This looked fine in the source but gitiles is very particular about its table syntax. Change-Id: I9ca8d61a5ca9656bc4f62297861540473485091a Reviewed-on: https://chromium-review.googlesource.com/c/breakpad/breakpad/+/3485499 Reviewed-by: Lei Zhang <thestig@chromium.org>
25 KiB
Introduction
Given a minidump file, the Breakpad processor produces stack traces that include function names and source locations. However, minidump files contain only the byte-by-byte contents of threads' registers and stacks, without function names or machine-code-to-source mapping data. The processor consults Breakpad symbol files for the information it needs to produce human-readable stack traces from the binary-only minidump file.
The platform-specific symbol dumping tools parse the debugging information the compiler provides (whether as DWARF or STABS sections in an ELF file or as stand-alone PDB files), and write that information back out in the Breakpad symbol file format. This format is much simpler and less detailed than compiler debugging information, and values legibility over compactness.
Overview
Breakpad symbol files are ASCII text files, with lines delimited as appropriate for the host platform. Each line is a record, divided into fields by single spaces; in some cases, the last field of the record can contain spaces. The first field is a string indicating what sort of record the line represents (except for line records; these are very common, making them the default saves space). Some fields hold decimal or hexadecimal numbers; hexadecimal numbers have no "0x" prefix, and use lower-case letters.
Breakpad symbol files contain the following record types. With some restrictions, these may appear in any order.
-
A
MODULE
record describes the executable file or shared library from which this data was derived, for use by symbol suppliers. A `MODULE' record should be the first record in the file. -
A
FILE
record gives a source file name, and assigns it a number by which other records can refer to it. -
A
FUNC
record describes a function present in the source code. -
A line record indicates to which source file and line a given range of machine code should be attributed. The line is attributed to the function defined by the most recent
FUNC
record. -
A
PUBLIC
record gives the address of a linker symbol. -
A
STACK
record provides information necessary to produce stack traces.
MODULE
records
A MODULE
record provides meta-information about the module the symbol file
describes. It has the form:
MODULE
operatingsystem architecture id name
For example: MODULE Linux x86 D3096ED481217FD4C16B29CD9BC208BA0 firefox-bin
These records provide meta-information about the executable or shared library
from which this symbol file was generated. A symbol supplier might use this
information to find the correct symbol files to use to interpret a given
minidump, or to perform other sorts of validation. If present, a MODULE
record
should be the first line in the file.
The fields are separated by spaces, and cannot contain spaces themselves, except for name.
-
The operatingsystem field names the operating system on which the executable or shared library was intended to run. This field should have one of the following values:
Value Meaning Linux Linux mac Macintosh OSX windows Microsoft Windows -
The architecture field indicates what processor architecture the executable or shared library contains machine code for. This field should have one of the following values:
Value Instruction Set Architecture x86 Intel IA-32 x86_64 AMD64/Intel 64 ppc 32-bit PowerPC ppc64 64-bit PowerPC unknown unknown -
The id field is a sequence of hexadecimal digits that identifies the exact executable or library whose contents the symbol file describes. The way in which it is computed varies from platform to platform.
-
The name field contains the base name (the final component of the directory path) of the executable or library. It may contain spaces, and extends to the end of the line.
FILE
records
A FILE
record holds a source file name for other records to refer to. It has
the form:
FILE
number name
For example: FILE 2 /home/jimb/mc/in/browser/app/nsBrowserApp.cpp
A FILE
record provides the name of a source file, and assigns it a number
which other records (line records, in particular) can use to refer to that file
name. The number field is a decimal number. The name field is the name of
the file; it may contain spaces.
FUNC
records
A FUNC
record describes a source-language function. It has the form:
FUNC
[m] address size parameter_size name
For example: FUNC m c184 30 0 nsQueryInterfaceWithError::operator()(nsID const&, void**) const
The m field is optional. If present it indicates that multiple symbols reference this function's instructions. (In which case, only one symbol name is mentioned within the breakpad file.) Multiple symbols referencing the same instructions may occur due to identical code folding by the linker.
The address and size fields are hexadecimal numbers indicating the start address and length in bytes of the machine code instructions the function occupies. (Breakpad symbol files cannot accurately describe functions whose code is not contiguous.) The start address is relative to the module's load address.
The parameter_size field is a hexadecimal number indicating the size, in
bytes, of the arguments pushed on the stack for this function. Some calling
conventions, like the Microsoft Windows stdcall
convention, require the called
function to pop parameters passed to it on the stack from its caller before
returning. The stack walker uses this value, along with data from STACK
records, to step from the called function's frame to the caller's frame.
The name field is the name of the function. In languages that use linker symbol name mangling like C++, this should be the source language name (the "unmangled" form). This field may contain spaces.
Line records
A line record describes the source file and line number to which a given range of machine code should be attributed. It has the form:
address size line filenum
For example: c184 7 59 4
Because they are so common, line records do not begin with a string indicating the record type. All other record types' names use upper-case letters; hexadecimal numbers, like a line record's address, use lower-case letters.
The address and size fields are hexadecimal numbers indicating the start address and length in bytes of the machine code. The address is relative to the module's load address.
The line field is the line number to which the machine code should be
attributed, in decimal; the first line of the source file is line number 1. The
filenum field is a decimal number appearing in a prior FILE
record; the name
given in that record is the source file name for the machine code.
The line is assumed to belong to the function described by the last preceding
FUNC
record. Line records may not appear before the first `FUNC' record.
No two line records in a symbol file cover the same range of addresses. However, there may be many line records with identical line and file numbers, as a given source line may contribute many non-contiguous blocks of machine code.
PUBLIC
records
A PUBLIC
record describes a publicly visible linker symbol, such as that used
to identify an assembly language entry point or region of memory. It has the
form:
PUBLIC [m] address parameter_size name
For example: PUBLIC m 2160 0 Public2_1
The Breakpad processor essentially treats a PUBLIC
record as defining a
function with no line number data and an indeterminate size: the code extends to
the next address mentioned. If a given address is covered by both a PUBLIC
record and a FUNC
record, the processor uses the FUNC
data.
The m field is optional. If present it indicates that multiple symbols reference this function's instructions. (In which case, only one symbol name is mentioned within the breakpad file.) Multiple symbols referencing the same instructions may occur due to identical code folding by the linker.
The address field is a hexadecimal number indicating the symbol's address, relative to the module's load address.
The parameter_size field is a hexadecimal number indicating the size of the
parameters passed to the code whose entry point the symbol marks, if known. This
field has the same meaning as the parameter_size field of a FUNC
record;
see that description for more details.
The name field is the name of the symbol. In languages that use linker symbol name mangling like C++, this should be the source language name (the "unmangled" form). This field may contain spaces.
STACK WIN
records
Given a stack frame, a STACK WIN
record indicates how to find the frame that
called it. It has the form:
STACK WIN type rva code_size prologue_size epilogue_size parameter_size saved_register_size local_size max_stack_size has_program_string program_string_OR_allocates_base_pointer
For example: STACK WIN 4 2170 14 1 0 0 0 0 0 1 $eip 4 + ^ = $esp $ebp 8 + = $ebp $ebp ^ =
All fields of a STACK WIN
record, except for the last, are hexadecimal
numbers.
The type field indicates what sort of stack frame data this record holds. Its
value should be one of the values of the
StackFrameTypeEnum
type in Microsoft's
Debug Interface Access (DIA) API.
Breakpad uses only records of type 4 (FrameTypeFrameData
) and 0
(FrameTypeFPO
); it ignores others. These types differ only in whether the last
field is an allocates_base_pointer flag (FrameTypeFPO
) or a program string
(FrameTypeFrameData
). If more than one record covers a given address, Breakpad
prefers FrameTypeFrameData
records over FrameTypeFPO
records.
The rva and code_size fields give the starting address and length in bytes of the machine code covered by this record. The starting address is relative to the module's load address.
The prologue_size and epilogue_size fields give the length, in bytes, of the prologue and epilogue machine code within the record's range. Breakpad does not use these values.
The parameter_size field gives the number of argument bytes this function
expects to have been passed. This field has the same meaning as the
parameter_size field of a FUNC
record; see that description for more
details.
The saved_register_size field gives the number of bytes in the stack frame dedicated to preserving the values of any callee-saves registers used by this function.
The local_size field gives the number of bytes in the stack frame dedicated to holding the function's local variables and temporary values.
The max_stack_size field gives the maximum number of bytes pushed on the stack in the frame. Breakpad does not use this value.
If the has_program_string field is zero, then the STACK WIN
record's final
field is an allocates_base_pointer flag, as a hexadecimal number; this is
expected for records whose type is 0. Otherwise, the final field is a program
string.
Interpreting a STACK WIN
record
Given the register values for a frame F, we can find the calling frame as follows:
- If the has_program_string field of a
STACK WIN
record is zero, then the final field is allocates_base_pointer, a flag indicating whether the frame uses the frame pointer register,%ebp
, as a general-purpose register.- If allocates_base_pointer is true, then
%ebp
does not point to the frame's base address. Instead,- Let next_parameter_size be the parameter size of the function
frame F called (not this record's parameter_size field), or
zero if F is the youngest frame on the stack. You must find this
value in F's callee's
FUNC
,STACK WIN
, orPUBLIC
records. - Let frame_size be the sum of the local_size field, the saved_register_size field, and next_parameter_size. > > With those definitions in place, we can recover the calling frame as follows:
- F's return address is at
%esp +
frame_size, - the caller's value of
%ebp
is saved at%esp +
next_parameter_size+
saved_register_size- 8
, and - the caller's value of
%esp
just before the call instruction was%esp +
frame_size+ 4
. > > (Why do we include next_parameter_size in the sum when computing frame_size and the address of the saved%ebp
? When a function A has called a function B, the arguments that A pushed for B are considered part of A's stack frame: A's value for%esp
points at the last argument pushed for B. Thus, we must include the size of those arguments (given by the debugging info for B) along with the size of A's register save area and local variable area (given by the debugging info for A) when computing the overall size of A's frame.)
- Let next_parameter_size be the parameter size of the function
frame F called (not this record's parameter_size field), or
zero if F is the youngest frame on the stack. You must find this
value in F's callee's
- If allocates_base_pointer is false, then F's function doesn't use
%ebp
at all. You may recover the calling frame as above, except that the caller's value of%ebp
is the same as F's value for%ebp
, so no steps are necessary to recover it.
- If allocates_base_pointer is true, then
- If the has_program_string field of a
STACK WIN
record is not zero, then the record's final field is a string containing a program to be interpreted to recover the caller's frame. The comments in the postfix_evaluator.h header file explain the language in which the program is written. You should place the following variables in the dictionary before interpreting the program:$ebp
and$esp
should be the values of the%ebp
and%esp
registers in F..cbParams
,.cbSavedRegs
, and.cbLocals
, should be the values of theSTACK WIN
record's parameter_size, saved_register_size, and local_size fields..raSearchStart
should be set to the address on the stack to begin scanning for a return address, if necessary. The Breakpad processor sets this to the value of%esp
in F, plus the frame_size value mentioned above.
If the program stores values for
$eip
,$esp
,$ebp
,$ebx
,$esi
, or$edi
, then those are the values of the given registers in the caller. If the value of$eip
is zero, that indicates that the end of the stack has been reached.
The Breakpad processor checks that the value yielded by the above for the calling frame's instruction address refers to known code; if the address seems to be bogus, then it uses a heuristic search to find F's return address and stack base.
STACK CFI
records
STACK CFI
("Call Frame Information") records describe how to walk the stack
when execution is at a given machine instruction. These records take one of two
forms:
STACK CFI INIT
address size register1: expression1 register2: expression2 ...
STACK CFI
address register1: expression1 register2: expression2 ...
For example:
STACK CFI INIT 804c4b0 40 .cfa: $esp 4 + $eip: .cfa 4 - ^
STACK CFI 804c4b1 .cfa: $esp 8 + $ebp: .cfa 8 - ^
The address and size fields are hexadecimal numbers. Each
registeri is the name of a register or pseudoregister. Each
expression is a Breakpad postfix expression, which may contain spaces, but
never ends with a colon. (The appropriate register names for a given
architecture are determined when STACK CFI
records are first enabled for that
architecture, and should be documented in the appropriate
stackwalker_
architecture.cc
source file.)
STACK CFI records describe, at each machine instruction in a given function, how to recover the values the machine registers had in the function's caller. Naturally, some registers' values are simply lost, but there are three cases in which they can be recovered:
-
You can always recover the program counter, because that's the function's return address. If the function is ever going to return, the PC must be saved somewhere.
-
You can always recover the stack pointer. The function is responsible for popping its stack frame before it returns to the caller, so it must be able to restore this, as well.
-
You should be able to recover the values of callee-saves registers. These are registers whose values the callee must preserve, either by saving them in its own stack frame before using them and re-loading them before returning, or by not using them at all.
(As an exception, note that functions which never return may not save any of this data. It may not be possible to walk the stack past such functions' stack frames.)
Given rules for recovering the values of a function's caller's registers, we can walk up the stack. Starting with the current set of registers --- the PC of the instruction we're currently executing, the current stack pointer, etc. --- we use CFI to recover the values those registers had in the caller of the current frame. This gives us a PC in the caller whose CFI we can look up; we apply the process again to find that function's caller; and so on.
Concretely, CFI records represent a table with a row for each machine instruction address and a column for each register. The table entry for a given address and register contains a rule describing how, when the PC is at that address, to restore the value that register had in the caller.
There are some special columns:
-
A column named
.cfa
, for "Canonical Frame Address", tells how to compute the base address of the frame; other entries can refer to the CFA in their rules. -
A column named
.ra
represents the return address.
For example, suppose we have a machine with 32-bit registers, one-byte instructions, a stack that grows downwards, and an assembly language that resembles C. Suppose further that we have a function whose machine code looks like this:
func: ; entry point; return address at sp
func+0: sp -= 16 ; allocate space for stack frame
func+1: sp[12] = r0 ; save 4-byte r0 at sp+12
... ; stuff that doesn't affect stack
func+10: sp -= 4; *sp = x ; push some 4-byte x on the stack
... ; stuff that doesn't affect stack
func+20: r0 = sp[16] ; restore saved r0
func+21: sp += 20 ; pop whole stack frame
func+22: pc = *sp; sp += 4 ; pop return address and jump to it
The following table would describe the function above:
code address | .cfa | r0 (on Google Code) | r1 (on Google Code) | ... | .ra |
---|---|---|---|---|---|
func+0 | sp | cfa[0] |
|||
func+1 | sp+16 | cfa[0] |
|||
func+2 | sp+16 | cfa[-4] |
cfa[0] |
||
func+11 | sp+20 | cfa[-4] |
cfa[0] |
||
func+21 | sp+20 | cfa[0] |
|||
func+22 | sp | cfa[0] |
Some things to note here:
-
Each row describes the state of affairs before executing the instruction at the given address. Thus, the row for func+0 describes the state before we execute the first instruction, which allocates the stack frame. In the next row, the formula for computing the CFA has changed, reflecting the allocation.
-
The other entries are written in terms of the CFA; this allows them to remain unchanged as the stack pointer gets bumped around. For example, to find the caller's value for r0 (on Google Code) at func+2, we would first compute the CFA by adding 16 to the sp, and then subtract four from that to find the address at which r0 (on Google Code) was saved.
-
Although the example doesn't show this, most calling conventions designate "callee-saves" and "caller-saves" registers. The callee must restore the values of "callee-saves" registers before returning (if it uses them at all), whereas the callee is free to use "caller-saves" registers without restoring their values. A function that uses caller-saves registers typically does not save their original values at all; in this case, the CFI marks such registers' values as "unrecoverable".
-
Exactly where the CFA points in the frame --- at the return address? below it? At some fixed point within the frame? --- is a question of definition that depends on the architecture and ABI in use. But by definition, the CFA remains constant throughout the lifetime of the frame. It's up to architecture- specific code to know what significance to assign the CFA, if any.
To save space, the most common type of CFI record only mentions the table entries at which changes take place. So for the above, the CFI data would only actually mention the non-blank entries here:
insn | cfa | r0 (on Google Code) | r1 (on Google Code) | ... | ra |
---|---|---|---|---|---|
func+0 | sp | cfa[0] |
|||
func+1 | sp+16 | ||||
func+2 | cfa[-4] |
||||
func+11 | sp+20 | ||||
func+21 | r0 (on Google Code) | ||||
func+22 | sp |
A STACK CFI INIT
record indicates that, at the machine instruction at
address, belonging to some function, the value that registern had
in that function's caller can be recovered by evaluating
expressionn. The values of any callee-saves registers not mentioned
are assumed to be unchanged. (STACK CFI
records never mention caller-saves
registers.) These rules apply starting at address and continue up to, but not
including, the address given in the next STACK CFI
record. The size field is
the total number of bytes of machine code covered by this record and any
subsequent STACK CFI
records (until the next STACK CFI INIT
record). The
address field is relative to the module's load address.
A STACK CFI
record (no INIT
) is the same, except that it mentions only those
registers whose recovery rules have changed from the previous CFI record. There
must be a prior STACK CFI INIT
or STACK CFI
record in the symbol file. The
address field of this record must be greater than that of the previous record,
and it must not be at or beyond the end of the range given by the most recent
STACK CFI INIT
record. The address is relative to the module's load address.
Each expression is a breakpad-style postfix expression. Expressions may contain
spaces, but their tokens may not end with colons. When an expression mentions a
register, it refers to the value of that register in the callee, even if a prior
name/expression pair gives that register's value in the caller. The exception is
.cfa
, which refers to the canonical frame address computed by the .cfa rule in
force at the current instruction.
The special expression .undef
indicates that the given register's value cannot
be recovered.
The register names preceding the expressions are always followed by colons. The expressions themselves never contain tokens ending with colons.
There are two special register names:
-
.cfa
("Canonical Frame Address") is the base address of the stack frame. Other registers' rules may refer to this. If no rule is provided for the stack pointer, the value of.cfa
is the caller's stack pointer. -
.ra
is the return address. This is the value of the restored program counter. We use.ra
instead of the architecture-specific name for the program counter.
The Breakpad stack walker requires that there be rules in force for .cfa
and
.ra
at every code address from which it unwinds. If those rules are not
present, the stack walker will ignore the STACK CFI
data, and try to use a
different strategy.
So the CFI for the example function above would be as follows, if func
were at
address 0x1000 (relative to the module's load address):
STACK CFI INIT 1000 .cfa: $sp .ra: .cfa ^
STACK CFI 1001 .cfa: $sp 16 +
STACK CFI 1002 $r0: .cfa 4 - ^
STACK CFI 100b .cfa: $sp 20 +
STACK CFI 1015 $r0: $r0
STACK CFI 1016 .cfa: $sp